Fridge running but not cooling: what to check first
4 min read · Table View, Cape Town
A fridge that hums but does not cool is the most common refrigeration call we get. Sometimes it is a five-minute fix. Sometimes it is the first sign that the sealed system has a leak. This checklist separates the two without opening anything you should not open.
Start with the simple things
Rule out the causes that do not need tools. A fridge pushed tight into a cupboard, a condenser coil matted with dust, or a door seal that no longer touches the frame can all make a healthy fridge look broken.
- Check the thermostat or control is not set to a warm position or holiday mode.
- Confirm the interior light goes off when the door closes.
- Feel the door seal all the way round with a sheet of paper: it should grip evenly.
- Pull the fridge out and clear at least a hand's width behind and above it.
- Vacuum or brush the condenser coil if it is visibly dusty.
- Check nothing is blocking the cold air vents inside the cabinet.
Listen for the fans
A frost-free fridge has two fans: one at the condenser at the back, one at the evaporator inside. Open the door and listen. If the interior fan is silent while the compressor runs, air is not moving across the coil and the fridge section will stay warm while the freezer works.
A clicking noise every few minutes usually points to the compressor start circuit, which is a repair rather than a maintenance item.
Frost patterns tell a story
Heavy frost on the back wall of a frost-free fridge, or ice building up in one corner of a freezer, suggests the defrost system is not completing its cycle. A failed heater, timer or termination sensor leaves ice on the evaporator, and the airflow passages gradually close.
Do not chip ice out with a knife. The evaporator tubes sit directly behind the plastic and a puncture turns a defrost repair into a sealed-system repair.
When it is likely a gas or compressor fault
If the compressor runs continuously, the condenser stays cool, and there is no frost pattern at all, the system may be low on refrigerant or the compressor may not be pumping. Both need pressure testing and electrical checks on site.
Tell us the make, model, age and current temperature when you enquire. If stock or food is at risk, say so, because that changes the priority.